IndicatorsandControls
Dataconnection
ThedataconnectiontotheEF‐2ismadeviaaNeutrik™EtherconRJ‐45connector.ItusesastandardEthernetpinoutwhichis
configuredusingthePolaritySwitch.Seeappendixforadetailedpinout.
DataStatusLEDs
AYellowindicationontheupperLEDmarked“TPRX”indicatesthatreceivedataisbeing detectedonthetwistedpair.ThelowerLED
indicatestheLinkstatusonthetwistedpair.Seeappendixformoredetail.
PolaritySwitch
Settingthisswitchto
or setsthepinoutofTXandRXtoaccommodateconnectiontovariousdevices.Withasettingof
“Auto”,theEF‐2willdeterminethecorrectpinoutsfortheTXandRX.Seetheappendixformoredetail.
DirectionalModeSwitch
TheOPTRXandOPTTXpositionsarebothunidirectionalmodes.IntheOPTRXposition,dataisreceivedbythefiberopticinputand
transmittedouttotheRJ‐45connector.IntheOPTTXpositiondataisreceivedbytheRJ‐45connectorandtransmittedtothefiber
opticoutput.TheTX/RXpositionisabidirectionalmodewhichactsasastandardEthernetconnection.Seetheappendixformore
detail.
FiberConnections
TheEF‐2comesstandardwithLCfiberconnectors.ST, tacticalgradeTAC‐4connectors,orNeutrik™OpticalConconnectorsareavailableasoptions.In
liveproductio nuse,itisrecommendedtofittheunitswithLCconnectorsandutilizetheVPL‐11,12,or13panelsco ntainin g1,2,or3,TAC‐4panel
mountconnectorsrespectively.TAC‐4JR–LCconnectorshaveLCpigtail swhichconnectwiththeLCconnectorsontheEF2.AlternatelytheTAC‐4FR
connectorcanbemounteddi rectlyonthechassisoftheEF2.Always besuretouseappropriatefiberandcompatibleconnectors.
FiberStatusLEDs
AYellowindicationontheupperLEDmarked“OPTRX”indicatesthatreceivedataisbeingdetectedonthefiberconnection.Thelower
LEDindicatestheLinkstatusonthefiberconnection.Seeappendixformore
detail.
PowerLED
AgreenLEDindicatesthepowersupplyisoperatingcor rectly.
DCPowerConnector
TheEF‐2canrunon9‐24VDCconnectedviathisconnector.
ACPowerConnector
TheEF‐2runsonafullrangeswitchingpowersupply.Itwillacceptvoltagesfrom90‐250
VAC.Thisconnectoralsoservesasafuse
holder.Replacefuseonlywitha1Amp250V(T1AL250V)slo‐blofuse.